Conversions in ETBase.cpp do not make sense
On lines 76, 100 and 110 of ETBase.cpp conversion factors are calculated in the following way:
if(u=="W/m2"){
conv=11.57; // W is 1 joule per second 1MJ/Day = 11.57 j/s =
}else if (u=="J/m2/day"){
conv=1;
}else if (u=="MJ/m2/day"){
conv=1000000;
The target unit is J/m2/day but converting W/m2 to that would require a conversion factor of 24*3600 = 84600.